G.SHDSL Port History of Near-End Performance window 128
Models 2616RC, 3096RC & 3196RC Admin Reference Guide 9 • G.SHDSL (Model 3096RC)
The G.SHDSL Port History of Near End Performance window also provides hyperlinks for returning to the Sys-
tem History and Port Details windows as shown in figure 62 on page 127. The following paragraphs describe
the contents of the G.SHDSL Port History of Near End Performance window.
Figure 63. System History Overview window (Model 3096RC shown)
Back To System History Page hyperlink
Click the Back To System History Page link (see figure 61 on page 127) to display the System History Overview
window (see figure 63). For a detailed description of the System History Overview window, see chapter 17, “Sys-
tem” on page 245.
To Port Details Page hyperlink
Click the To Port Details Page link (see figure 61 on page 127) to display the Port Details window. For a com-
plete description of The Port Details window, see section “G.SHDSL Port Details window” on page 113.
Error Statistics table
The G.SHDSL Port History of Near End Performance window displays G.SHDSL Port error statistics in a table
of 96 rows. Each row shows error statistics counted during a 15-minute interval, starting with the most recent
15-minute interval (at the top of the page) and moving chronologically backward as you scroll down the page.
The first row (row 1) shows the most recent 15-minute interval, Interval number 1. The last row (row 96)
shows the oldest 15-minute interval, Interval number 96. (15 minutes x 96 rows = 24 hours).
• G.SHDSL Port x (gshDSLIntervalNumber)—Indicates the number of the completed 15 minute interval.
The Interval Number may range from 1 to 96, where 1 is the most recently completed 15 minute interval
and 96 is the least recently completed 15 minute interval.
Columns in the Error Statistics table show the recorded values for the following G.SHDSL port statistics:
• Errored Seconds (ES) (historyESgshDSL)—Indicates the total cumulative number of seconds in which
there were one or more FIFO errors on this port during the 15-minute interval.