Patton electronic 2616RC Switch User Manual


 
The Chassis Management Channel statistics page 177
Models 2616RC, 3096RC & 3196RC Admin Reference Guide 11 • In-band management
Connection Details
IP Address (sysMgmtIpAddress)
Specifies the IP address of the Ethernet interface for the ForeFront module on the remote side of the Chassis
Management Channel). This IP address must identify another G.SHDSL or iDSL T-DAC in the same chassis
(or chassis segment in the 6676).
Status (sysMgmtStatus)
This is the current status of the connection. The status will either be down(0) or up(1). A status of down(0)
indicates that the card is trying to establish an IP connection with the remote T-DAC over the Chassis Man-
agement Channel. A status of up(1) means that the connection is up and is able to pass management data.
TX Port (sysMgmtPortTx)
Defines the port number on which the local T-DAC will transmit in-band management data. The port selected
must be the same as that selected for the receive port at the remote T-DAC. Parameter values range from
port1(1) through port32(32).
Tx TimeSlot (sysMgmtSlotTx)
Defines the timeslot that the local T-DAC will use to transmit in-band management data. The specified
timeslot value must be the same as that used for the receive timeslot parameter at the remote T-DAC. Valid
parameter values are positive integers ranging from 1–128.
Rx Port (sysMgmtPortRx)
Defines the port number on which the local T-DAC will receive in-band management data. The port selected
must be the same as that selected for the transmit port at the remote T-DAC. Parameter values range from
port1(1) through port32(32).
Rx TimeSlot (sysMgmtSlotRx)
Defines the timeslot that the local T-DAC will use to receive in-band management data. The specified timeslot
value must be the same as that used for the transmit timeslot parameter at the remote T-DAC. Valid parameter
values are positive integers ranging from 1–128.
HDLC Statistics
LINK Resets (sysMgmtResets)
Indicates the number of HDLC link resets since the T-DAC module was last rebooted or power-cycled. A link
reset occurs whenever the HDLC connection is re-established after going down. A high number of transmis-
sion errors on the link may cause the link to go down.
Transmit Octets (sysMgmtTxOctets)
Indicates the total number of octets transmitted on the link since the PPP link was last rebooted or power-
cycled.
Transmit Frames (sysMgmtTxMessageEnds)
Indicates total number of HDLC frames transmitted since the PPP link was last rebooted or power-cycled.
Receive Octets (sysMgmtRxOctets)
Indicates the total number of octets received since the PPP link was last rebooted or power-cycled.