Near End Line Statistics—History 303
Models 2616RC, 3096RC & 3196RC Admin Reference Guide 20 • T1/E1 Link
Degraded Minutes (dsx1CurrentDMs)
The number of degraded minutes (DMs) encountered by a DS1 interface in the current 15-minute interval.
Line Code Violations (dsx1CurrentLCVs)
The number of line code violations (LCVs) encountered by a DS1 interface in the current 15-minute interval.
Near End Line Statistics—History
Click on Near End Line Statistics—History to display line statistics for prior completed 15-minute intervals
within the last 24 hours (see figure 168). This does not include the current 15-minute interval.
Figure 168. History of Near End Performance window
Interval (dsx1IntervalNumber)
A number between 1 and 96, where 1 is the most recently completed 15-minute interval and 96 is the least
recently completed 15-minutes interval. When all 96 intervals are visible, then the T-DAC has been operating
(powered-on) for at least 24 hours. If less than 96 intervals are visible, then it has been less than 24 hours since
the T-DAC was powered up.
Errored Seconds (dsx1intervaless)
The number of errored Seconds encountered by a DS1 interface in one of the previous 96, individual 15-
minute, intervals.
Severely Errored Seconds (dsx1IntervalSESs)
The number of severely errored seconds encountered by a DS1 interface in one of the previous 96, individual
15-minute, intervals.