Patton electronic 2616RC Switch User Manual


 
G.SHDSL Port Details window 119
Models 2616RC, 3096RC & 3196RC Admin Reference Guide 9 • G.SHDSL (Model 3096RC)
History Details table
Note
The title for the History Details table also functions as a hyperlink.
Click the History Details link to display the G.SHDSL Port History of
Near-End Performance window which provides a record of errors
counted on this port during the last 24 hours in 15-minute intervals
(see section “G.SHDSL Port History of Near-End Performance win-
dow” on page 127 for more information).
The History Details table displays the current values of the following G.SHDSL port statistics variables:
Port Up-Time (d:h:m:s)
(gshDSLTotalDay) (gshDSLTotalHour) (gshDSLTotalMin) (gshDSLTotalSec)
Total length of time in days:hours:minutes:seconds since the downloaded state changed to yes(1) this port.
This value is reset when the T-DAC powers down. (When the T-DAC first powers up the value of down-
loaded is no(0).)
Link Up-Time (d:h:m:s)
(gshDSLAvailableDay) (gshDSLAvailableHour) (gshDSLAvailableMin) (gshDSLAvailableSec)
Total Length of time in days:hours:minutes:seconds since the link state for this port last changed to up(1).
This value is reset when the link goes down.
Unavailable Time (d:h:m:s)
(gshDSLUnAvailableDay) (gshDSLUnAvailableHour) (gshDSLUnAvailableMin) (gshDSLUnAvailableSec)
Total cumulative time in days:hours:minutes:seconds (since the last power cycle) that the link state for this
port has been down(0).
Errored Sec
(gshDSLErroredSec)
The total cumulative number of seconds in which there were one or more FIFO errors on this port since the
counter was last reset.
Severely Errored Sec
(gshDSLSeverlyErroredSec)
The total cumulative number of seconds in which there were one or more CRC errors on this port since the
counter was last reset.