Fujitsu Cloud Edition V3.1.0 Server User Manual


 
reboot_count
Enter the number of times to reboot. Enter a number from 1 to 3.
Power Monitoring Device Data
- Section Name
Enter [PowerDevice] as the section name.
- Section Header
operation
Enter the desired operation for the current line. Enter a hyphen ("-") to skip this line.
device_name
Enter the name that will be used to identify the power monitoring device.
Enter a character string beginning with an alphabetical character and containing up to 15 alphanumeric characters and hyphens
("-").
Note
Device names should be unique between all power monitoring devices. The names are case-sensitive.
ip_address
Enter the same IP address as that set on the power monitoring device.
Enter a string of numeric values (between 0 and 255) and periods.
Note
IP addresses should be unique between all resources.
snmp_community_name
Enter the same SNMP community (read-only permission) as that set on the power monitoring device.
Enter a string of up to 32 alphanumeric characters, underscores ("_"), and hyphens ("-").
voltage
Enter the voltage (V) that is being supplied to the power monitoring device. Enter a number between 10 and 999.
Note
Resource Orchestrator calculates power consumption data using the electrical current value obtained from the power monitoring
device and its specified voltage.
comment (optional)
Enter any comments for the power monitoring device.
Enter up to 128 alphanumeric characters or symbols (ASCII characters 0x20 to 0x7e).
Note
A line break is counted as one character. Use "Alt+Enter" to enter line breaks.