Table 4-26. Predefined Address Variables
Address Variable Value/Description
@INTERNAL@. The address of the Access Control Server Administrative Console. By default this is
42.0.0.1, but if you have reconfigured the address range for the internal DHCP server
used for providing NAT addresses, this will be the first address in that range.
@INTRANET@ The network address of the subnet on which the Access Control Server resides
@LOGON_SERVER@ The IP address of the Logon Access Control Server. In a redundancy/failover
configuration, this is always the IP address of the original primary Access Control
Server, and remains so even when failover has occurred and the original Access
Control Server is no longer functioning. Logon requests to @LOGON_SERVER@ are
redirected to the Access Control Server currently acting as primary
@SERVER@ The IP address of the Access Control Server. In a redundancy/failover configuration,
this is the IP address of the Access Control Server currently acting as primary.
Four of the five built-in addresses can only be modified by changing the network configuration of your
700wl Series system through the Network Setup page. The exception is the
@INTRANET@ address, which
you can change by entering it as if it were a user variable.
You can modify the
@INTRANET@ variable by creating a new @INTRANET@ variable and providing a
different network address. This creates a new entry in the table and overrides the old value. You cannot
replace any of the other pre-defined variables this way—they reflect the values input during the
network setup, and can be changed only by changing the network configuration on the Network Setup
tab under the Network button.
» To create a user-defined address variable, click New Address... .
You can edit any user-defined variable by clicking on the variable name. User-defined variables
will act as links to the Edit Address page.
The Edit Address page appears, as shown in Figure 4-35.
Figure 4-35. Creating or Editing an Address Variable
Table 4-27 defines these two fields: