no cluster heartbeat
Function: In the commander switch, set interval of sending heartbeat packets among the
switches of the cluster; the “no cluster heartbeat” command restores the default setting.
Parameter: <interval> is the interval of heartbeat of the cluster, valid range is 1 to 65535.
Command mode: The interval of heartbeat is 8 seconds by default.
Default: Global Mode
Usage Guide: In the commander switch, this command is used to set the interval of
heartbeat. And this information is distributed to all the member switches. If this
command is executed in a non-commander switch and the value is more than
the current holdtime, the setting is invalid and an error is displayed.
Example: Set the interval of sending heartbeat packets of the cluster to 10 seconds.
Switch(config)#cluster heartbeat 10
18.2.2.13 clear cluster candidate-table
Command: clear cluster candidate-table
Function: Clear the list of candidate switches discovered by the commander switch.
Command mode: Admin Mode
Usage Guide: In the commander switch, this command is used to clear the list of
candidate switches discovered by the commander switch. If this command is
executed in a non-commander switch, an error will be displayed.
Example: Clear the list of candidate switches discovered by the commander switch
Switch#clear cluster candidate-table