ADC Release 3.1 Network Card User Manual


 
1152700 Issue 1 February 2001 Section 2 Operation and Maintenance
Page 2-110
2000, ADC Telecommunications, Inc.
DLP-713
Page 4 of 5
Cellworx Vision Alarm Filter
Apply
X
Close
Network Elements/Ring:
Selected Network Elements/Ring:
>>
<<
All >>
<< All
>>
<<
All >>
<< All
>>
<<
All >>
<< All
>>
<<
All >>
<< All
Ring System 1
T1 Multi 1
DS1 Channelized Fra
Fiber Fragment
Critical
Major
Resource:
Severity:
Generic Trouble:
Selected Generic Trouble:
Selected Severity:
Selected Resource:
Alarm Indication Signal
Alarm Indication Signal
Active NMIC lost conne
All
Burst Errored Seconds
C-bit Coding Violations
C-bit Errored Seconds T
C-bit Severely Errored S
informational
Cleared
Minor
E1 Multi 1
T3 CRS
Housekeeping Alarm
NE Isolated
NMIC
No information Availabl
NE-1
NE-2
NE-3
NMIC
10899-D
SELECTABLE NEs AND SYSTEMS
ARE LISTED HERE. SELECT
INDIVIDUALS OR ALL AND HIT THE
>> KEY TO MOVE TO SELECTED
BOX.
SELECTABLE RESOURCES ARE
LISTED HERE. SELECT INDIVIDUALS
OR ALL AND HIT THE >> KEY TO
MOVE THEM TO THE SELECTED BOX.
SELECTABLE SEVERITIES ARE
LISTED HERE. SELECT INDIVIDUALS
OR ALL AND HIT THE >> KEY TO
MOVE THEM TO THE SELECTED BOX.
SELECTABLE GENERIC TROUBLES
ARE L;ISTED HERE. SELECT
TROUBLES OR ALL AND HIT THE
>> KEY TO MOVE THEM TO THE
SELECTED BOX.
SELECTED NEs ARE MOVED
HERE FOR ALARM RETRIEVAL.
SELECTED RESOURCES ARE
MOVED HERE FOR ALARM
RETRIEVAL.
SELECTED ALARM SEVERITIES
ARE MOVED HERE FOR ALARM
RETRIEVAL.
SELECTED GENERIC TROUBLES
ARE MOVED HERE FOR ALARM
RETRIEVAL.
T3 TMUX Multi 1
TMUX EXP
Timing Control Circuit
Cellworx 1
Figure 713-3. Cellworx Vision Alarm Filter Window
Table 713-2. Cellworx Vision Alarm Filter Resource List
RESOURCE DESCRIPTION
155 MM or SM CRS Selects alarms for an OC3 resource.
155 Ring, 622 Ring, 2488 Ring Selects the alarms for a Ring Interface Card.
E1 Multi 1 or T1 Multi 1 Selects the alarms for selected card type.
Protection Groups Selects alarms related to card protection.
T3 CRS, T3 TMUX, TMUX EXP Selects alarms for the T3 cards.
Shelf Controller Selects alarms related to SC modules.
Ring Selects alarms related to the ring network.
<user defined NE Name> Selects alarms on a particular NE(s).
Fiber Fragment Selects alarms for the Fiber Fragment.
Housekeeping Alarm Selects alarms for the Housekeeping Alarm.
NE Isolated Selects alarms for the NE Isolated.
NMIC Selects alarms for the NMIC.
No Information Available Selects alarms that do not have enough
information available to define.
Timing Control Circuit Selects alarms related to the system timing.