ADC Release 3.1 Network Card User Manual


 
1152700 Issue 1 February 2001 Section 2 Operation and Maintenance
Page 2-265
© 2000, ADC Telecommunications, Inc.
DLP-758
Page 3 of 3
Table 758-1. 155 RIC Configuration Options, continued
SELECTION DEFAULT OPTIONS DEFINITION
Signal
Degrade BER
Threshold
5 5 through 9 Defines the number of bit errors the port can incur
before a signal degrade occurs and generates an
alarm message and probably protection switch.
Medium Type SONET SONET
SDH
Not configurable on RIC cards.
Loopback
towards
None None
Terminal
Facility
No loopback activated on this card.
Sends cells back to the cellbus and back out to the
ring. No changes are made to the path layer data.
Loops the incoming signal back to the CPE and
generates AIS to the cellbus.
Line Coding NRZ Not configurable by user.
Line Type Card
Dependent
sonetOther
sonetShortSingle
Mode
sonetLongSingle
Mode
sonetMultiMode
Not configurable by user, type dependent on card
installed. This will show sonetLongSingleMode for
RICs and 155 SM cards, and sonetMultiMode for
155 MM cards.
Transmit Path
Trace
(example)
NE1_Slot17_
Port1 (OC48)
Card position dependent. This is assigned by the
system according to the NE and slot it is equipped in.