ADC Release 3.1 Network Card User Manual


 
1152700 Issue 1 February 2001 Section 2 Operation and Maintenance
Page 2-144
2000, ADC Telecommunications, Inc.
DLP-726
Page 2 of 4
THRESHOLD CONFIGURATION
9. Users may specify error counts required to trip a system alarm by clicking on the
Configure Thresholds button at the bottom of the PM Data window. This will bring up a
Performance Monitoring Configuration window similar to Figure 726-3.
10. To configure the thresholds, place the cursor in the individual count boxes and type in the
new threshold value. Do this for all the thresholds to be set in the Section, Line, and Path
tabs. Refer to Table 726-1 for valid values. Once all counts are entered in each box, select
the Apply button at the bottom of the screen to send the new data to the database. The
Apply button includes each tab in the request.
Stop! You have completed this procedure.
Cellworx Vision: Performance Monitoring - Statistics
X
Resource: NE-1
Apply
Close
Interval
Slot / Card Type
Sonet
DS1/E1
DS3
PLCP
ATM / TC
AAL1
Layer
SELECT A SLOT AND CARD
TYPE, INDIVIDUAL OR
MULTIPLE, TO DISPLAY THE
PORTS IN THE NEXT WINDOW.
CLOSES PM STATISTICS
WINDOW.
SELECT THE PM LAYER(S)
TO BE RETRIEVED.
SELECT TO RETRIEVE PM
DATA FOR SELECTED
PARAMETERS.
SELECT THE CURENT
COUNT OR A HISTORICAL
TIME PERIOD FOR ONE
SLOT/PORT. USER CANNOT
SELECT CURRENT AND A
HISTORICAL AT THE SAME
TIME.
SELECT AN NE FOR PM
RETRIEVAL AND THE SLOT
AND CARD TYPES IN THE
SHELF WILL BE DISPLAYED
IN THE NEXT WINDOW.
11743-D
Port
Slot 16 / Port 1
Slot 16 / Port 2
Slot 17 / Port 1
Slot 17 / Port 2
Slot 5 / Port 1
- Channel 1
- Channel 2
- Channel 3
- Channel 4
- Channel 5
current
00:00-00:15
00:15-00:30
00:30-00:45
00:45-01:00
01:00-01:15
01:15-01:30
01:30-01:45
01:45-02:00
0200 - 02:15
NE-1
NE-2
NE-3
Cellworx1
Cellworx2
Cellworx3
SELECT THE PORT(S) DESIRED
TO DISPLAY THE LAYERS
AVAILABLE IN THE NEXT
WINDOW.
Slot 17 / 622 Ring
Slot 16 / 622 Ring
Slot 5 / T3 TMUX Multi 1
Slot 6 / 155 SM CRS
Slot 7 / 155 SM CRS
Slot 8 / 155 SM CRS
Slot 9 / 155 SM CRS
Slot 10 / T3 CRS
Slot 11 / T3 CRS
Slot 12 / T1 Multi 1
Figure 726-1. Performance Monitoring – Selection Window