ADC Release 3.1 Network Card User Manual


 
1152700 Issue 1 February 2001 Section 2 Operations and Maintenance
Page 2-428
© 2000, ADC Telecommunications, Inc.
TAP-100
Page 9 of 23
Table 4-1. Alarm Identifications, continued
ALARM
MESSAGE
SEVERITY IMPACT DESCRIPTION SUGGESTED COURSE OF ACTION
Errored
Seconds
Section
Threshold
Crossing
Alert
ES-Stca
Informati
onal
Alert
Service
Degradation
ES violations threshold
crossing alert for section
layer at local NE. A one
second interval in the
transmission from the far
end originating NE has had
an error at the section layer
causing an Errored Second
Section (ESS). ESS errors
have exceeded the user
definable threshold level.
Check input levels and signal
sources. Increase threshold
settings if necessary. Check
local requirements for proper
levels.
ESTca
Errored
Seconds
Threshold
Crossing
Alert
Informati
onal
Alert
Service
Degradation
Errored seconds threshold
crossing alert for reported
port.
Check input levels and signal
sources. Increase threshold
settings if necessary. Check
local requirements for proper
levels.
Excessive
Ber
Critical Service
Affecting
Excessive Bit Error Rate
count.
Applies to all SONET cards.
Extended Cell
Layer Cell
Bus Interface
Fault
EclCellbusInter
faceFault
Extended Cell
Layer Egress
Router Fault
EclEgressRout
erFault
Extended Cell
Layer Ingress
Router Fault
EclIngressRout
erFault
Extended Cell
Layer Utopia
Interface
Fault
EclUtopiaInterf
aceFault
Major Service
Affecting
Cell bus hard failure. Each of these alarms indicate a
switch fabric failure. Check
alarm messages, is the failure
on both buses? One card? All
cards? If single card failure,
remove from backplane, check
pins in backplane connector,
and reseat. One card failure
could pull down the entire bus.
Pull each card out one at a time
starting with protect, check the
pins in the backplane connector,
monitor system traffic for
recovery, then reseat the card.
Perform switch over via GUI or
craft interfaces before pulling
EIMs if necessary. Do not pull
the working cards. Repeat
procedure for SC TEIM in slot
18 at the rear of the shelf. This
is a bus termination and the
system will crash without it.
Far End Loss
Of Signal
LOS-FE
Critical Service
Outage
No input signal is being
provided at the far end.
Check input connections at the
far end and transmitting
equipment into the far end low
speed facility.
(continued)