Page 3 of 3
Table 756-1. 2488 RIC Configuration Options, continued
SELECTION DEFAULT OPTIONS DEFINITION
Signal
Degrade BER
Threshold
5 5 through 9 Defines the number of bit errors the port can incur
before a signal degrade occurs and generates an
alarm message and probably protection switch.
Medium Type SONET SONET
SDH
Not configurable on RIC. This is determined by the
dip-switch on the SC EIM, which sets the shelf type.
Loopback
towards
None None
Terminal
Facility
No loopback activated on this card.
Sends cells back to the cellbus and back out to the
ring. No changes are made to the path layer data.
Loops the incoming signal back to the CPE and
generates AIS to the cellbus.
Line Coding NRZ Not configurable by user.
Line Type Card
Dependant
sonetOther
sonetShortSingle
Mode
sonetLongSingle
Mode
sonetMultiMode
Not configurable by user, card type dependant on
card inserted.
Transmit Path
Trace
(example)
NE1_Slot17_
Port1 (OC48)
Card position dependent. This is assigned by the
system according to the NE and slot it is equipped in.