ALARM CUT-OFF (ACO)
Summary: This procedure instructs the operator in the steps required to perform an alarm cut-
off on a node in the Cellworx node. An alarm cut off disables the shelf audible alarm for any
currently active alarm conditions. Any alarm conditions that are activated subsequently will
reenact the audible alarm until the alarm conditions are cleared, or the operator reinitiates the
ACO condition. An ACO will not extinguish any visual or message indications; visible
indications shall be changed from unacknowledged (i.e., flashing) to acknowledged (constant).
The user must have gained access to the Cellworx Graphical User Interface (GUI) before
performing this procedure.
1. From the GUI main screen, select the node that will have the ACO activated on it by double
clicking on it using the left mouse button. The shelf level GUI Chassis View window
appears similar to the one shown in Figure 776-1.
2. Select the Fault pull-down menu using the left mouse button or by entering Alt+F.
3. Select the Execute Alarm Cut-Off on the menu using the left mouse button or by entering
Alt+C.
4. The system responds with a confirmation message as shown in Figure 776-2. Select OK to
continue with the ACO or Cancel to abort the operation.
Stop! You have completed this procedure.
Cellworx Vision: Chassis View, Network Element 2
File Configuration Fault Security
S
C
N
M
I
C
S
C
6
2
2
R
i
n
6
2
2
R
i
n
X
T
3
T
M
U
X
T
M
U
X
E
X
T
1
M
u
l
t
i
T
3
C
R
S
T
3
C
R
S
E
1
M
u
l
t
E
1
M
u
l
t
SELECT THE FAULT PULLDOWN
MENU USING LEFT MOUSE
BUTTON OR BY PRESSING THE
ALT+A KEYS SIMULTANEOUSLY.
13473-C
Configure Housekeeping Alarms
Execute Alarm Cut-Off
Figure776-1. Shelf Level Alarm Cut-Off Window
Alarm Cut-off
Are you sure you want to execute an
Alarm Cut-Off?
OK
?
Cancel
14572-A
Figure 776-2. Alarm Cut-Off Confirmation Window