ADC Release 3.1 Network Card User Manual


 
1152700 Issue 1 February 2001 Section 2 Operations and Maintenance
Page 2-285
© 2000, ADC Telecommunications, Inc.
DLP-764
Page 2 of 3
Table 764-1. Display T1 Multi 1 Card Status Definitions
ITEM STATUS DEFINITION ACTION
Operational
State
Up
Down
Unknown
Card is functioning properly.
Card is not functioning
properly, is in reset mode, or
failed. Check Admin state.
The shelf controller does not
currently know the operational
status.
No action required.
Verify card is installed, check for failure
indications, or provision card for service
per DLP-755.
Wait a few seconds for operations to
complete and update the screen.
Availability
State
Available
In Test
Failed
Power Off
Not Installed
Off Line
Dependency
Unknown
Card is ready for processing
commands.
Card is currently processing
test signals.
Card has failed operation and
system has placed it out of
service.
No power to the card.
Card is not currently installed
in selected slot of the shelf.
Card is installed and
provisioned but currently off
line.
Card is supplying timing
reference, traffic, or other data
to the system.
The system processor does not
currently know the availability
status.
No action required.
Wait a few seconds for screen to update.
Card may be performing a reset, or the
bus may be busy.
Check power source, replace card if
source is good per DLP-777.
If required, install card in selected slot
per DLP-777 and provision per DLP-
755.
If required, set module on line per DLP-
755.
Perform a soft switch over (manual) per
DLP-771 to release card dependency if
removing.
Wait for processor to update current
status, may need to perform a manual
reset of SC per DLP-773.
Protection
State
Not
Protected
Enabled
Manual
Switch
Forced
Switch
Lockout
Unknown
Not Protected
Protection is available for
selected card but is not active.
User has manually switched
the card to protection.
User has forced card to
protection.
Card cannot switch to
protection. It has been locked
out by command or switch
count.
Protection status information
is not available to the shelf
controller.
If equipped, set up a protection group
and provision card for protection per
DLP-753.
No action necessary.
If required, switch the card back per
DLP-771.
If required, release forced switch per
DLP-771.
If required, release manual lock-out per
DLP-771.
Wait a few minutes and update screen.
May need to reset SC, refer to DLP-773.
(continued)