ADC Release 3.1 Network Card User Manual


 
ADCP-70-220 Issue 1 November 2000 Section 2 Operation and Maintenance
Page 2-9
© 2000, ADC Telecommunications, Inc.
NTP-002
Page 2 of 2
7. Launch the Cellworx Vision Graphical User Interface (GUI). DLP-705
8. After the GUI boots up, it will prompt the user to synchronize
the database. Choose the active NMIC’s database as the correct
database to synchronize.
9. Perform a discovery for a new Cellworx STN ring network. DLP-706
10. Set the Date and Time on the NMIC. DLP-707
11. Set the System Identifier for each node. DLP-767
12. After all nodes are successfully discovered, configure them
before adding any expansion shelves. Configuration may include
timing configuration, locking ports to remove LOS alarms,
configuring the max VC bits to greater than zero to allow VC
connections for each port, etc. NTP-006
13. Refresh the GUI screen so the nodes will display the new names. DLP-718
14. Perform acceptance tests on the new nodes per local
requirements. NTP-011
15. Add expansion shelves to the ring nodes if equipped. NTP-005
16. Save the NMIC database. DLP-745
Stop! You have completed this procedure.