ADC Release 3.1 Network Card User Manual


 
1152700 Issue 1 February 2001 Section 2 Operations and Maintenance
Page 2-332
© 2000, ADC Telecommunications, Inc.
DLP-780
Page 6 of 10
26. From the slot_2 NMIC shell, install the AIC/RIC and SCC software images by entering the
following commands:
/sbin/cwupgrade /tmp/p3/AicSccSwImages-3.0.1-2.ppc.rpm
27. From the slot_4 NMIC shell, install the AIC/RIC and SCC software images on the slot_4
NMIC by entering the following commands:
/sbin/cwupgrade /tmp/p3/AicSccSwImages-3.0.1-2.ppc.rpm
28. From the slot_2 NMIC shell, install the AIC/RIC and SCC bootrom flash images by
entering the following commands:
/sbin/cwupgrade /tmp/p3/AicSccBootroms-3.0.1-2.ppc.rpm
29. From the slot_4 NMIC shell, install the AIC/RIC and SCC software images by entering the
following commands:
/sbin/cwupgrade /tmp/p3/AicSccBootroms-3.0.1-2.ppc.rpm
30. Install the AIC bootrom flash patch image on the slot 2 NMIC:
/cellworx/bin/installFlashImage aic 2.1.0.25 /tmp/p3/bootrom.2.1.0.25.bin
31. Install the AIC bootrom flash patch image on the slot 4 NMIC:
/cellworx/bin/installFlashImage aic 2.1.0.25 /tmp/p3/bootrom.2.1.0.25.bin
32. From the slot_2 NMIC shell, enter the following commands to install the Cellworx NMIC
software:
/sbin/cwupgrade /tmp/p3/cellworx-3.0.1.0-1.ppc.rpm
/sbin/cwupgrade /tmp/p3/cellworx-3.0.1.0p-1.ppc.rpm
33. From the slot_4 NMIC shell, install the Cellworx NMIC software:
/sbin/cwupgrade /tmp/p3/cellworx-3.0.1.0-1.ppc.rpm
/sbin/cwupgrade /tmp/p3/cellworx-3.0.1.0p-1.ppc.rpm
34. From the slot_2 NMIC shell, install the Feature Package software by entering the following
command and replacing the “x” with an a, or c depending on the feature package ordered:
/sbin/cwupgrade /tmp/p3/FeatureControl_a(x)-3.0-1.ppc.rpm
35. From the slot_4 NMIC shell, install the Feature Package software by entering the following
command and replacing the “x” with an a, or c depending on the feature package ordered:
/sbin/cwupgrade/tmp/p3/FeatureControl_a(x)-3.0-1.ppc.rpm