ADC Release 3.1 Network Card User Manual


 
1152700 Issue 1 February 2001 Section 2 Operation and Maintenance
Page 2-146
2000, ADC Telecommunications, Inc.
DLP-726
Page 4 of 4
Table 726-1. SONET Layer PM Values, continued
MONITOR TYPE COMMENTS
LINE
CV-L 16383 Line Code Violation, count of BIP errors detected at the Section layer using the B2
byte in the incoming SONET signal
CV-LFE 16383 Far-end Line Code Violation, a count of BIP errors detected at the far end LTE and
reported back to the near end LTE using the Remote Error Indicator (REI) in the
Line overhead
ES-L 900 Line Errored Seconds, number of seconds in which at least one Line layer BIP, or an
AIS condition was detected
ES-LFE 900 Far-end Line Errored Seconds, count of the seconds in which at least one Line BIP
was detected by the far end LTE or an RDI-L defect was present
SES-L 900 Line Severely Errored Seconds, a count of seconds in which a set number of Line
layer BIP errors, or an AIS condition were detected
SES-LFE 900 Far-end Line Severely Errored Seconds, a count of seconds in which a set number of
Line layer BIP errors, or AIS were detected by the far end LTE
UAS-L 900 Line Unavailable Seconds, a count of seconds in which the Line was considered
unavailable
UAS-LFE 900 Far-end Line Unavailable Seconds, a count of seconds in which the Line was
considered unavailable, reported by the far end LTE to the near end LTE using the
RDI in the Line overhead
PATH
CV-P 16383 Code Violation, a count of BIP errors detected at the Path layer using the B3 byte of
the incoming SONET signal
CV-PFE 16383 Far-end Path Code Violation, a count of BIP errors detected at the far end LTE and
reported back to the near end LTE using the Remote Error Indicator (REI) in the
Path overhead
ES-P 900 Path Errored Seconds, number of seconds in which at least one Path layer BIP,
Alarm Indication Signal (AIS), or Loss Of Pointer (LOP) condition was detected
ES-PFE 900 Far-end Path Errored Seconds, count of the seconds in which at least one Path layer
BIP was detected by the far end LTE or an RDI-P defect was present
SES-P 900 Path Severely Errored Seconds, a count of seconds in which a set number of Path
BIP errors, AIS, or LOP were detected
SES-PFE 900 Far-end Path Severely Errored Seconds, a count of seconds in which a set number of
Path layer BIP errors, AIS, or LOP were detected by the far end LTE and reported
back to the near end LTE using the RDI-P bit in the Path overhead
UAS-P 900 Line Unavailable Seconds, a count of seconds in which the Line was considered
unavailable
UAS-PFE 900 Far-end Path Unavailable Seconds, a count of seconds in which the Path was
considered unavailable, reported by the far end LTE to the near end LTE using the
RDI in the Path overhead