ADC Release 3.1 Network Card User Manual


 
1152700 Issue 1 February 2001 Section 2 Operation and Maintenance
Page 2-236
© 2000, ADC Telecommunications, Inc.
DLP-751
Page 3 of 3
Table 751-1. 622 RIC Card Configuration Options, continued
SELECTION DEFAULT OPTIONS DEFINITION
Signal
Degrade BER
Threshold
5 5 through 9 Defines the number of bit errors the port can incur
before a signal degrade occurs and generates an
alarm message and probably protection switch.
Medium Type SONET SONET
SDH
Not configurable on RIC. This is determined by the
dipswitch on the SC EIM, which sets the shelf type.
Can be SONET, Synchronous Optical Network, US,
or Synchronous Digital Hierarchy, European
standard for transporting data over fiber.
Loopback
towards
None None
Terminal
Facility
No loopback activated on this card.
Sends cells back to the cellbus and back out to the
ring. No changes are made to the path layer data.
Loops the incoming signal back to the CPE and
generates AIS to the cellbus.
Line Coding NRZ Not configurable by user.
Line Type
Card
Dependant
SonetOther
sonetShortSingle
Mode
sonetLongSingle
Mode
sonetMultiMode
Not configurable by user, dependant on card type
inserted.
Transmit Path
Trace
(example)
NE1_Slot17_
Port1 (OC12)
Card position dependent. This is assigned by the
system according to the NE and slot it is equipped in.
1