ADC Release 3.1 Network Card User Manual


 
1152700 Issue 1 February 2001 Section 2 Operation and Maintenance
Page 2-266
© 2000, ADC Telecommunications, Inc.
DLP-759
Page 1 of 3
RETRIEVE 622 RING INTERFACE CARD (RIC) STATUS
Summary: This procedure defines the information retrieved from the shelf level GUI card status
display for the 622 RIC card. User must have the GUI launched and accessed the shelf level GUI
display per NTP-007 prior to performing this procedure.
1. Double click on the 622 RIC located in slot 16 or 17 in the shelf level GUI “Chassis
View”at the top of the window.
2. Click the small block between the Status and Configuration sections and drag it downwards
to view all the status information. Refer to Table 759-1 for definitions of status information
provided.
3. Select the Close button to return to the shelf view.
Stop! You have completed this procedure.
Cellworx Vision: Card View - 622 Ring Interface Card
Status:
Apply Chassis View
Refresh Close
X
Card Level
Operational State:
Availability State:
Port Level
NE Name: Cellworx1
NE Id: 1
Card: 622 Ring
Slot Number: 17
Port Number: 1
Status
Active
1
Port
ADC
622
Ring
Up
Available
Section Status: Line Status: Path Status:
No Alarm
TC Alarm Status:
Configuration:
Port Level
Timing
LOF
LOS
No Alarm
No Alarm
AIS
RDI
STS LOP
STS AIS
STS RDI
Unequipped
Signal Label
Mismatch
Synachronization Status:
Recieve Path Trace:
Diagnostics
ST3
No Alarm
NE3_Slot16_Port1 (OC12)
APPLIES CHANGES
AND SENDS TO SHELF
CONTROLLER.
RETURNS TO CHASSIS
VIEW WITHOUT CLOSING
CARD LEVEL VIEW.
REPAINTS WINDOW
TO REFLECT ANY
CHANGES.
CLOSES CARD LEVEL
VIEW AND RETURNS TO
SHELF LEVEL VIEW.
PERFORMS TEST
OVER FIBER
LINK.
CLICK ON BOX AND DRAG
UP OR DOWN TO EXPAND
STATUS OR CONFIGURATION
VIEWS.
13444-B
Figure 759-1. 622 RIC Status Window