ADC Release 3.1 Network Card User Manual


 
1152700 Issue 1 February 2001 Section 2 Operation and Maintenance
Page 2-157
2000, ADC Telecommunications, Inc.
DLP-729
Page 3 of 4
Cellworx Vision: PM Threshold Configuration AAL1 Layer
Card Type
X
T1 MULTI
Slot-Port ESs SESs SEFSs UASs CSS
S4-P1
00000
Close
Apply
13563-B
Figure 729-3. Performance Monitoring T1 Multi Port Configuration Window
Table 729-1. T1 Multi 1 CRS Performance Monitoring Values
MONTYPE MAX 15 MIN.
THRESHOLD
COMMENTS
CV-L 16383 Sets a count of line code violations that the port can incur before creating a
TCA on the system. Line code violation is a count of *BPVs and *ExZs.
ES-L 900 Sets a count of line errored seconds that the port can incur before creating a
TCA on the system. ES-L is determined as number of seconds that BPV and
ExZ >=1 or LOS (loss of Signal) >=1.
SES 900 Sets a count of line severely errored seconds that the port can incur before
creating a TCA on the system. SES is determined as the number of seconds
CV-L >=1547 or LOS (Loss of Signal) >=1.
CV-P 16383 Sets a count of path code violations that the port can incur before creating a
TCA on the system. CV-P determined from SF count of FE, or ESF count of
CRC errors.
UAS 900 Sets a count of unavailable seconds that the port can incur before creating a
TCA on the system. UAS determined as the number of seconds that the path is
unavailable.
BES 900 Sets a count of Burst Errored Seconds that the port can incur before creating a
TCA on the system.
CSS 900 Sets a count of Controlled Slip Seconds that the port can incur before
creating a TCA on the system. CSS is determined as a count of 1 second
intervals where CS >=1.
SEFS 900 Sets a count of severely errored frame seconds that the port can incur before
creating a TCA on the system. SEFS determined when SEF >=1.
DM 2 Sets a count of minutes that the port can incur a signal degradation before
creating a TCA on the system.
ES 900 Sets a count of errored seconds that the port can incur before creating a TCA
on the system. Error seconds determined as number of seconds FE>=1, SEF
>=1, or any Cellworx Vision/AIS condition.
(continued)