ADC Release 3.1 Network Card User Manual


 
1152700 Issue 1 February 2001 Section 2 Operation and Maintenance
Page 2-264
© 2000, ADC Telecommunications, Inc.
DLP-758
Page 2 of 3
Cellworx Vision: Card View - 155 Ring Interface Card
Status:
Apply Chassis View
Refresh
Status
Active
Protect
Timing
Close
X
Configuration:
Card Level
Administrative State: Congestion Thresholds:
Locked
Unlocked
Ingress:
Egress:
80
80
%
%
Port Level
Administrative State: Transmit Timing Source:
Locked
Unlocked
System
Recieved
NE Name: Cellworx1
NE Id: 16
Card: 155 Ring
Slot Number: 16
Port Number: 1
Port
ADC
155
Ring
1
Status
Active
Timing
NE16_slot116_Port1(OC3)
Do not use for synchronization
SONET
Medium Type:
SDH
Transmit Path Trace:
Diagnostics
Line Coding:
Line Type:
NRZ
Long range single-mode fiber
APPLIES CHANGES
AND SENDS TO SHELF
CONTROLLER.
RETURNS TO CHASSIS
VIEW WITHOUT CLOSING
CARD LEVEL VIEW.
REPAINTS WINDOW
TO REFLECT ANY
CHANGES.
CLOSES CARD LEVEL
VIEW AND RETURNS TO
SHELF LEVEL VIEW.
PERFORMS TEST
OVER FIBER
LINK.
CLICK ON BOX AND DRAG
UP OR DOWN TO WIDEN
STATUS OR CONFIGURATION
VIEWS.
CLICK ON BOX AND DRAG UP
OR DOWN TO WIDEN PORT
LEVEL VIEW.
USE SLIDERS TO VIEW
HIDDEN SELECTIONS.
155 MBPS PORT LEVEL
CONFIGURATION OPTIONS.
CARD LEVEL
CONFIGURATION OPTIONS.
NE AND CARD TYPE/
SLOT INFORMATION.
CARD REPRESENTATION
WITH REAL TIME ALARM
INDICATIONS.
0026-051
Ring Selection :
Auto Ring 16 Ring 17
Enable Signal Degrade
Signal Degrade BER Threshold: 10E-
5
Figure 758-1. 155 RIC Configuration Screen
Table 758-1. 155 RIC Configuration Options
SELECTION DEFAULT OPTIONS DEFINITION
Admin State Unlock Lock / Unlock Disables or enables the card or port for service.
Congestion
Threshold
80 0-100 Percentage of buffer capacity that will cause a
congestion threshold notification.
Ring
Selection
Auto
Auto
Ring 16
Ring 17
Not configurable on RIC cards.
Transmit
Timing
Source
System System
Received
Uses Primary timing reference.
Uses clock derived from incoming receive fiber (also
known as Line-Timing).
Do Not Use
for Sync
False Selected (true)
Not selected
(false)
If “True”, causes the RIC to output DUS (Do not Use
for Sync) in the S1 byte of the SONET overhead.
Enable Signal
Degrade
Not Selected Selected
Not Selected
Enables a protection switch of the traffic if the input
signal strength drops below tolerable levels set by the
user in the BER threshold selection.
(continued)