ADC Release 3.1 Network Card User Manual


 
1152700 Issue 1 February 2001 Section 2 Operation and Maintenance
Page 2-137
2000, ADC Telecommunications, Inc.
DLP-723
Page 5 of 5
Table 723-1. Subnetwork Connection Configuration Options
SELECTION OPTIONS DESCRIPTION
Connection Name User Defined Displays the connection name selected for
configuration. User may rename the connection
by typing in a new name and hitting Apply.
Segment Endpoint Single selection box Sets this end of the connection as a segment
endpoint for OAM cells.
Ingress / Egress NDC On or Off Enables or disables the network data collection for
selected circuit.
Test Type End to End OAM
Segment OAM
Continuity Check Source
Continuity Check Sync
No Test No test is currently being administered.
Loopback Location ID Customer assigned location identifier, used to
loopback the incoming signal and transmit it back
to the customer equipment, limited to 16 numeric
characters.
Insert Loopback Cells Towards Access Facility
Towards Ring Facility
Test Status None
Active
Test is not currently active.
Test is currently in progress.