ADC Release 3.1 Network Card User Manual


 
1152700 Issue 1 February 2001 Operation and Maintenance
Page 2-387
© 2000, ADC Telecommunications, Inc.
DLP-788
Page 2 of 3
Table 788-1. Display FT1 FRS Card Status Definitions
ITEM STATUS DEFINITION ACTION
CARD LEVEL
Operational
State
Up
Down
Unknown
Card is functioning properly.
Card is not functioning
properly, is in reset mode, or
failed. Check Admin state.
The shelf controller does not
currently know the operational
status.
No action required.
Verify card is installed, check for failure
indications, or provision card for service
per DLP-785.
Wait a few seconds for operations to
complete and update the screen.
Availability
State
Available
In Test
Failed
Power Off
Not Installed
Off Line
Dependency
Unknown
Card is ready for processing
commands.
Card is currently processing
test signals.
Card has failed operation and
system has placed it out of
service.
No power to the card.
Card is not currently installed
in selected slot of the shelf.
Card is installed and
provisioned but currently off
line.
Card is supplying timing
reference, traffic, or other data
to the system.
The system processor does not
currently know the availability
state.
No action required.
Wait a few seconds for screen to update.
Card may be performing a reset, or the
bus may be busy.
Check power source, replace card if
source is good per DLP-777.
If required, install card in selected slot
per DLP-777 and provision per DLP-
785.
If required, set module on line per DLP-
785.
Wait for processor to update current
status, may need to perform a manual
reset of SC per DLP-773.
Protection
Status
Not
Protected
Not Protected Protection operation on FRS cards is not
available with release 3.1 software.
(continued)