ADC Release 3.1 Network Card User Manual


 
1152700 Issue 1 February 2001 Section 2 Operation and Maintenance
Page 2-273
© 2000, ADC Telecommunications, Inc.
DLP-761
Page 2 of 3
Table 761-1. T3 CRS Card Status Definitions
ITEM STATUS DEFINITION ACTION
Operational
State
Up
Down
Unknown
Card is functioning properly.
Card is not functioning properly,
is in reset mode, or failed. Check
Admin state.
The shelf controller does not
currently know the operational
status.
No action required.
Verify card is installed, check for
failure indications, or provision card
for service per DLP-753.
Wait a few seconds for operations to
complete and update the screen.
Availability
State
Available
In Test
Failed
Power Off
Not Installed
Off Line
Dependency
Unknown
Card is ready for processing
commands.
Card is currently processing test
signals.
Card has failed operation and
system has placed it out of
service.
No power to the card.
Card is not currently installed in
selected slot of the shelf.
Card is installed and provisioned
but currently off line.
Card is supplying timing
reference, traffic, or other data to
the system.
The system processor does not
currently know the availability
status.
No action required.
Wait a few seconds for screen to
update.
Card may be performing a reset, or
the bus may be busy.
Check power source, replace card if
source is good.
If required, install card in selected
slot per DLP-777 and provision per
DLP-753.
If required, set module on line per
DLP-753.
Perform a soft switch over (manual)
per DLP-771 to release card
dependency if removing.
Wait for processor to update current
status, may need to perform a
manual reset of SC per DLP-773.
Protection State
Not
Protected
Enabled
Manual
switch
Forced
Switch
Lockout
Unknown
Not Protected
Protection is available for
selected card but is not active.
User has manually switched the
card to protection.
User has forced card to
protection.
Card cannot switch to protection.
It has been locked out by
command or switch count.
Protection status information is
not available to the shelf
controller.
If equipped, set up a protection
group and provision card for
protection per DLP-765.
No action necessary.
If required, switch the card back per
DLP-771.
If required, release forced switch per
DLP-771.
If required, release manual lock-out
per DLP-771.
Wait a few minutes and update
screen. May need to reset SC, refer
to DLP-773.
(continued)