ADC SWD4573I1 Switch User Manual


 
Monitoring Frame Relay Performance Statistics
302 Avidia System Configuration and Management User Manual
Monitoring FRF.5 Statistics
You access frame relay FRF.5 statistics from the ::frf5=> prompt. From the
::frame-relay=> prompt, type frf5 then press to display the ::frf5=>
prompt.
From the ::frf5=> prompt, type the following command then press to display the
FRF.5 statistics.
show <fslot.port>
Parameter
<fslot.port>
The frame card slot and port.
Example
::frf5=> show 5.3
A screen similar to the following displays.
The following information displays:
The frame card slot number and port number in the format slot.port (for example, port 5.1).
The DLCI (Data Link Connection Identifier) for this virtual circuit.
The cross connect frame relay PVCC. This consists of the line card VPI, VCI and the
channel card VPI, VCI.
The number of frames received on this frame relay PVCC.
The number of frames sent on this frame relay PVCC.
The number of frames received in error on this frame relay PVCC.
The number of frames discarded by FR-SSCS on this frame relay PVCC.
ENTER
ENTER
::frf5=> show 5.3
FRF5 statistics for Frame Relay port 5.3 dlci 16:
Cross connect PVC: 0,38 0,1026
number of frames received on this pvc 0
number of frames sent on this pvcc 110
number of frames received in error on this pvcc 0
number of frames discarded by FR-SSCS on this pvcc 0