ADC SWD4573I1 Switch User Manual


 
Configuring SDSL Cell Alarm Profiles
402 Avidia System Configuration and Management User Manual
The SDSL Cell Alarm Profile Table window displays the configured SDSL cell alarm profiles.
Click and if necessary to view the entire table. displays the beginning of the table.
displays the next page of the table.
Adding SDSL Cell Alarm Profiles
You add SDSL cell alarm profiles from the SDSL Cell Alarm Profile Table window.
1 In the
Loss of Cell Delineation box, type a value for this threshold, or type 0 to disable the
trap.
The loss of cell delineation threshold determines the acceptable number of seconds in a
15-minute SDSL cell performance data collection period during which some cells
transmitted during that second were lost.
2 In the
Severe Loss of Cell Delineation box, type a value for this threshold, or type 0 to disable
this trap.
The severe loss of cell delineation threshold determines the acceptable number of seconds
in a 15-minute SDSL cell performance data collection period during which the total number
of LOCD events in that second exceed 50% of the total bandwidth available during that
second.