Configuring SPVCs
456 Avidia System Configuration and Management User Manual
Adding SPVCs
1 In the SPVC Configuration window, click .
The
Add SPVC Configuration window displays.
2 In the
Admin Status box, select Up to activate the SPVC or select Down to deactivate it.
3 In the
Channel Slot and Port boxes, select the channel card slot and port.
4 In the
Channel VPI and VCI boxes, type the VPI and VCI of the PVCC between the CPE and
the line card.
5 If the PVCC uses a frame channel card, in the Channel Encap box select the Encapsulation
mode (options:
LLC_8023 or VC_MUX_8023).
6 In the
Destination ATM Address box, type the ATM address of the destination ATM end
system.
The address can be up to 20 octets. The first octet must be 39, 45, or 47. Each octet must
be separated by a colon.
7 In the
Destination Retry Interval box, type a retry interval value between 0 and 3600.
The retry interval is the number of seconds the system waits before reattempting to
establish the SPVC after a failed call attempt.