Chapter 20: Configuring Subscriber Services
Avidia System Configuration and Management User Manual 395
CONFIGURING SDSL FRAME ALARM PROFILES
SDSL alarm profiles determine the conditions that generate SNMP traps. When the configured
thresholds are met or exceeded, the SNMP agent sends a trap to the configured trap receiver(s).
Only one trap is sent for each 15-minute data collection period. You assign SDSL alarm profiles
to ports during port configuration. A default profile exists with an index of 1. You cannot delete
the default profile.
To configure an SDSL alarm profile:
1 Open the
SDSL Port Configuration window (see “Configuring SDSL Frame Service” on
page 397).
2 Click the Alarm Profile Browse button.
The
SDSL Alarm Profile Table window displays the configured SDSL alarm profiles. Click
and if necessary to view the entire table. displays the beginning of the table.
displays the next page of the table.
Adding SDSL Frame Alarm Profiles
1 In the Alarm Setting LOSW box, select the desired Loss of Sync Word alarm setting (disable,
enable).
A Loss of Sync Word alarm occurs when one of the SDSL loops is out of sync.
2 In the
Alarm Setting Margin box, select the desired margin alarm setting (disable, enable).
3 In the
Alarm Setting ES box, select the desired errored seconds alarm setting (disable, enable).