ADC SWD4573I1 Switch User Manual


 
Configuring APS
432 Avidia System Configuration and Management User Manual
4 If you selected Revertive in Step 3, in the Wait Time To Revert box type the number of seconds
that you want the system to wait before switching traffic from the protection channel back
to the working channel after a failure on the main channel has been cleared. Otherwise, skip
this step.
The range is 300 to 720 seconds. The default is 300 seconds.
5 Do one of the following:
To activate the settings and close the
APS Configuration window, click Set, then in the
confirmation dialog click
Back.
Click
Get to cancel the new settings. You can only cancel the new settings if you have
not clicked
Set.
Issuing Manual APS Commands
Once APS is enabled, if the APS is currently set to either Non Revertive mode, you can override
the configured APS operation by selecting one of the following APS commands. After issuing
a manual APS command, you must issue a
Clear command to resume the configured APS
operation.
1 In the Switch Command box, select the desired manual APS command.
Clearclears any of the following manual commands.
Lockout Protectiondisables APS.
Force to Protectionswitches traffic to the protection channel.
Force to Workingswitches traffic to the working channel.
To Working If Readyswitches traffic to the working channel if there are not other
conditions (such as the configured Wait To Revert Time or a failure condition) that
prohibit switching to that channel.
2 Do one of the following:
To activate the settings and close the
APS Configuration window, click Set, then in the
confirmation dialog click
Back.
Click
Get to cancel the new settings. You can only cancel the new settings if you have
not clicked
Set.