ADC SWD4573I1 Switch User Manual


 
Monitoring SDSL Frame Alarms
332 Avidia System Configuration and Management User Manual
A screen similar to the following displays.
The following table describes the SDSL frame alarm history information that displays when you
type the display alarm command.
Alarm Type Description
Slot
Port
The slot and port of the card for which the alarm
information is displayed.
LOSW Loss of Sync Word. The number of seconds during
which one of the SDSL frame loops was out of sync.
Margin (Network/Customer) The number of seconds the actual margin exceeded
the configured threshold.
ES (Network/Customer) Errored Seconds. The number of seconds during
which errors occurred that prevented the payload
from being corrected.
UAS (Network/Customer) Unavailable Seconds. The number of seconds during
which the line was unavailable. Unavailable seconds
are seconds during which the SDSL frame loop is not
synchronized.
::frame=>alarm 3.7
Network Customer
Port LOSW Margin ES UAS Margin ES UAS
3.7 0 0 0 0 0 0 0
::frame=>alarm
Network Customer
Port LOSW Margin ES UAS Margin ES UAS
3.1 0 0 0 0 0 0 0
3.2 0 0 0 0 0 0 0
3.3 0 0 0 0 0 0 0
3.4 0 0 0 0 0 0 0
3.5 0 0 0 0 0 0 0
3.6 0 0 0 0 0 0 0
3.7 0 0 0 0 0 0 0