ADC SWD4573I1 Switch User Manual


 
Monitoring System Hardware Status
340 Avidia System Configuration and Management User Manual
MIN Chassis minor alarm LED status. Indicates whether a minor alarm
condition exists. Displays either OFF or ON.
AUD Indicates whether an audio alarm is activated. Displays either OFF
or ON.
FAN1, FAN2, FAN3, FAN4 Chassis fan LED status. Displays either OFF or ON.
PWR_MIN Power minor alarm LED status. Indicates whether a power minor
alarm condition exists. Displays either OFF or ON.
IP1 and IP2 Chassis input power 1 and input power 2 LED status. Indicate
whether the battery is providing -48 Vdc power. Displays either
OFF (not providing power) or ON (providing power).
FU1 and FU2 Chassis fuse 1 and Chassis fuse 2 LED status. Indicate whether the
fan tray fuses have blown. Displays either OFF (fuses have blown)
or ON (fuses are OK).
Port The port on which the most serious alarm in the system is
occurring.
Card Description A description of the card on which the most serious alarm is
occurring.
Most_Serious_Alarm The most serious alarm type that is occurring in the system.
Options:
PSFailureAlarm
One or more chassis power inputs is down.
FanFailureAlarmOne or more of the four chassis fans is
down.
ConfigChangeAlarm
A configuration change has occurred.
TempExceedThreshAlarmThe chassis temperature has
exceeded the allowable threshold. This threshold is not user
configurable.
LineCardDown alarmThe management card cannot
communicate with the line card.
CellBusDown alarm
The cell bus is not operational.
Severity The severity of the most serious alarm that is occurring in the
system.
Information Description