ADC SWD4573I1 Switch User Manual


 
Configuring and Initiating OAM Loopbacks
562 Avidia System Configuration and Management User Manual
5 In the Function Type box, select the loopback type (Segment or End-To-End).
Segment loopbacks test the connectivity between any two uniquely addressable points in a
VPC or VCC.
End-to-end loopbacks test the connectivity between any uniquely addressable point in the
VPC or VCC and any end point (such as a modem or a network end point) where a VPC or
VCC terminates.
6 In the
Destination Location ID box, type the OAM Location ID of the target device where the
cells will be looped back to the originating device (format xx:xx:xx:xx:xx:xx:xx:xx:
xx:xx:xx:xx:xx:xx:xx:xx where x is an integer 0 - 9 or an alpha character a - f). It is not
necessary to modify this value when you perform a loopback test to a Megabit Modem.
7 In the
Count box, type the total number of cells to be sent in the loopback (cells are sent one
at a time).
8 In the Time Out (sec) box, type the number of seconds allowed for the looped back cells to
return to the originating device before the loopback is designated as failed.
9 In the Delay (sec) box, type the number of seconds the system to waits between transmitted
cells.
10 In the Loopback Completion Trap box, select Send to send a trap when the loopback is
completed or select
Do Not Send if you do not want the management card to send a trap.
11 Do one of the following:
To activate the settings and close the
Add OAM Loopback Entry window, click Set, then in
the confirmation dialog click
Back.
To return to the
OAM Loopback Table window without deleting the table entry, click
Cancel.