ADC SWD4573I1 Switch User Manual


 
Chapter 20: Configuring Subscriber Services
Avidia System Configuration and Management User Manual 403
3 In the SNR box, type a value for this threshold, or type 0 to disable the trap.
The signal-to-noise ratio threshold determines how much margin can be dropped before the
number of bit errors exceeds the ratio of 1x10
-7
errored bits per bits transmitted.
4 Click
Add to add the SDSL cell alarm profile.
Deleting SDSL Cell Alarm Profiles
1 In the SDSL Cell Alarm Profile Table window, locate the table row that contains the SDSL cell
alarm configuration profile you want to delete.
Click and if necessary to view the entire table. displays the beginning of the
table. displays the next page of the table.
2 Select the
Delete check box next to the row that contains the profile you want to delete. To
select the
Delete check box for all rows (except the default profile, which cannot be
deleted), click
Check All.
If you decide not to delete a selected row, clear the
Delete check box next to the row. Click
Clear All to clear the Delete check box for all rows.
3 Click
Delete Checked Row(s) to delete the profiles.
A confirmation dialog displays.
4 Do one of the following:
Click
OK to delete the selected table rows.
Click
Cancel to not delete the table rows.
You cannot delete profiles that are assigned to ports.