ADC SWD4573I1 Switch User Manual


 
Chapter 25: Monitoring Subscriber Connections
Avidia System Configuration and Management User Manual 509
Current State (Upstream/Downstream) The current status of the ADSL loop. Options:
noDefect
There are no errors on the line.
lossOfLinkThe ATU-C was unable to link with the
ATU-R.
lossOfFraming
The line is not receiving valid
frames.
lossOfSignal
The line is not receiving valid
signal.
lossOfPower
The line is not receiving power.
lossOfSignalQualityThe margin has fallen
below the configured target margin or the BER
exceeds 10
-7
.
dataInitFailureThe ATU was unable to initialize.
configInitFailure
The ATU was unable to
initialize because the ATU at the other end does not
support the requested configuration.
protocolInitFailure
The ATU was unable to
initialize because of an incompatible protocol used
by the peer at the other end.
noPeerAtuPresent
The ATU was unable to
initialize because no activation sequence was
detected from the ATU at the other end.
Vendor ID (ATU-R/ATU-C) The vendor ID of the ATU-C and the ATU-R. not
allocated means there is no ATU-R present in the
circuit.
Version Number (ATU-R/ATU-C) The version number of the ATU-C and the ATU-R.
Status Box Description