Configuring IDSL Alarm Profiles
410 Avidia System Configuration and Management User Manual
4 In the Daily SES box, type the desired severely errored second threshold in seconds, or type 0
to disable this trap. The range is 0 to 2047, with 25 as the default.
The Daily SES Threshold is the number of severely errored seconds that must be met or
exceeded on the IDSL line within a day for an alarm to display. A severely errored second
generates when the number of block errors (CRC violations) defined by the SES threshold
parameter (see “Adding ADSL Line Profiles” on page 387) are detected during a one
second interval.
5 Click
Add to add the IDSL alarm profile.
Deleting IDSL Alarm Profiles
1 In the IDSL Alarm Configuration Profile Table window, locate the table row that contains the
IDSL alarm configuration profile you want to delete.
Click and if necessary to view the entire table. displays the beginning of the
table. displays the next page of the table.
2 Select the
Delete check box next to the row that contains the profile you want to delete. To
select the
Delete check box for all rows (except the default profile, which cannot be
deleted), click
Check All.
If you decide not to delete a selected row, clear the
Delete check box next to the row. Click
Clear All to clear the Delete check box for all rows.
3 Click
Delete Checked Row(s) to delete the profiles.
A confirmation dialog displays.
4 Do one of the following:
• Click
OK to delete the selected table rows.
• Click
Cancel to not delete the table rows.