ADC SWD4573I1 Switch User Manual


 
Chapter 20: Configuring Subscriber Services
Avidia System Configuration and Management User Manual 389
The ADSL Alarm Profile Table window displays the configured ADSL alarm profiles. Click
and if necessary to view the entire table. displays the beginning of the table.
displays the next page of the table.
Adding ADSL Alarm Profiles
You add ADSL Alarm profiles from the ADSL Alarm Profile Table window.
1 In the
Upstream and Downstream 15 Minutes Threshold Loss of Frame boxes, type a value for
this threshold, or type 0 to disable the trap.
The loss of frame threshold determines the acceptable number of seconds in a 15-minute
ADSL performance data collection period during which the frames lose sync on the ADSL
interface. In a normal environment with sufficient margin, a typical loss of frame threshold
value is 10.
2 In the
Upstream and Downstream 15 Minutes Threshold Loss of Signal boxes, type a value for
this threshold, or type 0 to disable this trap.
The loss of signal threshold determines the acceptable number of seconds in a 15-minute
ADSL performance data collection period during which the line power falls below the
target margin threshold. In a normal environment with sufficient margin, a typical loss of
signal threshold value is 10.