Cisco Systems OL-7396-01 Network Router User Manual


 
5-13
ATM Switch Router Software Configuration Guide
OL-7396-01
Chapter 5 Configuring Redundancy
Displaying the Switch Processor EHSA Configuration (Catalyst 8540 MSR)
SWC SLOT SWC_TYPE SWC_STATUS
=================================================
5 EVEN ACTIVE
6 NOT-PRESENT NOT-PRESENT
7 ODD ACTIVE
<information deleted>
Displaying the Switch Processor EHSA Configuration
(Catalyst 8540 MSR)
To display the switch processor EHSA configuration, use the following privileged EXEC command:
The following example shows the primary switch processor EHSA configuration:
Switch# show capability primary
Dram Size is :64 MB
Pmem Size is :4 MB
Nvram Size is :512 KB
BootFlash Size is :8 MB
ACPM hw version 5.2
ACPM functional version 4.0
Netclk Module present flag :16
NCLK hw version 3.1
NCLK func version 8.0
Printing the parameters for Switch card: 0
SWC0 HW version 7.2
SWC0 Functional version 1.2
SWC0 Table memory size: 0 MB
SWC0 Feat Card Present Flag: 0
SWC0 Feat Card HW version 0.0
SWC0 Feat Card Functional version 0.0
Printing the parameters for Switch card: 1
SWC1 HW version 0.0
SWC1 Functional version 0.0
SWC1 Table memory size: 0 MB
SWC1 Feat Card Present Flag: 0
SWC1 Feat Card HW version 0.0
SWC1 Feat Card Functional version 0.0
Printing the parameters for Switch card: 2
SWC2 HW version 7.2
SWC2 Functional version 1.2
SWC2 Table memory size: 0 MB
SWC2 Feat Card Present Flag: 0
SWC2 Feat Card HW version 0.0
SWC2 Feat Card Functional version 0.0
Number of Controller supported in IOS: 7
Command Purpose
show capability {primary | secondary} Displays the switch redundancy
configuration.