Cisco Systems OL-7396-01 Network Router User Manual


 
3-26
ATM Switch Router Software Configuration Guide
OL-7396-01
Chapter 3 Initially Configuring the ATM Switch Router
Testing the Configuration
Confirming the Software Version
Use the show version command to confirm the correct version and type of software and the
configuration register are installed:
Switch# show version
Cisco Internetwork Operating System Software
IOS (tm) PNNI Software (cat8540m-WP-M), Version XX.X(X), RELEASE SOFTWARE
Copyright (c) 1986-1998 by cisco Systems, Inc.
Compiled XXX XX-XXX-XX XX:XX by
Image text-base: 0x600108B4, data-base: 0x6057A000
ROM: System Bootstrap, Version XX.X(X) RELEASE SOFTWARE
Switch uptime is 1 hour, 1 minute
System restarted by reload
System image file is "tftp://cat8540m-wp-mz_nimmu"
cisco C8540MSR (R5000) processor with 65536K/256K bytes of memory.
R5000 processor, Implementation 35, Revision 2.1 (512KB Level 2 Cache)
Last reset from power-on
1 Ethernet/IEEE 802.3 interface(s)
8 ATM network interface(s)
507K bytes of non-volatile configuration memory.
16384K bytes of Flash PCMCIA card at slot 0 (Sector size 128K).
8192K bytes of Flash internal SIMM (Sector size 256K).
Configuration register is 0x0
Confirming Power-on Diagnostics
Power-on diagnostics test the basic hardware functionality of the system when it is power cycled, when
it is reloaded with a new version of power-on diagnostics software, or when you online insert and remove
(OIR) a module. The power-on diagnostics test the route processors, switch processors, port adapters,
interface modules.
Example (Catalyst 8540 MSR)
The following example displays the power-on diagnostic tests results for the Catalyst 8540 MSR:
Switch# show diag power-on
Cat8540 Power-on Diagnostics Status (.=Pass,F=Fail,U=Unknown,N=Not Applicable)
-----------------------------------------------------------------------------
Last Power-on Date: 1999/07/28 Time: 11:06:12
BOOTFLASH: . PCMCIA-Slot0: . PCMCIA-Slot1: .
CPU-IDPROM: . NVRAM-Config: .
ETHSRAM: . DRAM: . SARSRAM: .
PS0: . PS2: N PS (12V): .
FAN: . Temperature: . Bkp-IDPROM: .
Ethernet-port Access: . Ethernet-port CAM-Access: .
Ethernet-port Loopback: . Ethernet-port Loadgen: .
Power-on Diagnostics Passed.