3Com 9000 Switch User Manual


 
LECS ELAN Database Operations
259
Add ELAN
Add an ELAN to the LECS database, that is, add a new LES. Specify the
ELAN name and LES ATM address.
You can use any legal ELAN name. The names of the ELANs on a
particular switch all have the form
elan_<XXXX>_<n>
where
<XXXX>
is a number unique to the switch and
<n>
is the sequential number of
the ELAN between 0 and 15. This is the form to use for ELANs that you
enter in this section.
If the requested LES ATM address already exists in the LECS database, this
command defines a new
alias
ELAN with the same LAN type and frame
size. If the LES ATM address does not match any ATM address in the LECS
database, a new ELAN is created with the LAN type and max frame size
set to the default values (Ethernet, 1516).
You can define up to 380 ELANs in the LECS database of a
CoreBuilder 9000 ATM Enterprise Switch. Each CoreBuilder 9000 ATM
Enterprise Switch LECS database has 16 default ELAN names and default
ATM addresses corresponding to the LESs in the same switch.
Command Actions
Command Result
Enter menu sequence:
(2) LEM: LAN Emulation
(1) LCS: LE Configuration Service
(5) LNT: LECS Network topology
(6) ANE: Add new ELAN record
Enter a parameter at the prompt
Parameter Format or Range
ELAN name Up to 32 characters. For more information, see “Add
ELAN” on page 259.
ATM Address 20 Hex bytes separated by dots
Direct access sequence:
2 1 5 6
[parameters]
System action taken:
The specified ELAN is added to the LECS database.
System message display:
New elan was added.