3Com 9000 Switch User Manual


 
Setting Interface Parameters
389
Set ABR
Administrative
Weight
Sets the ABR Administrative Weight parameter. The ABR administrative
weight is the administrative weight of this interface port for the available
bit rate service category.
Command Actions
Command Result
Example
Enter:
1 1 9 4 4 2 5 19000
The following message is displayed:
Default value is 5040, new value is set to 19000
Press ENTER to continue...
Enter menu sequence:
(1) SYS: Platform Configuration
(1) SET: Switch setup
(9) PNI: PNNI Setup
(4) CFP: Configure PNNI
(4) ICF: Interface Configuration
(2) IPR: Interface Parameters
(5) ABW: ABR Admin Weight
Enter a parameter at the prompt
Parameter
Format or Range
ABR admin weight 1 - 2147483647
Direct access sequence:
1 1 9 4 4 2 5
[parameters]
System action taken:
.The ABR admin weight parameter is updated to its
new value.
System message display:
Default Value is 5040, New value is
set to <n>.