3Com 9000 Switch User Manual


 
LAN Emulation Statistics
311
Restart ELAN
Disconnect the control distribute channel to all LECs that are attached to
the specified ELAN.
This feature enables the user to reset the LANE Services without
rebooting the CoreBuilder 9000 for the following purposes:
Shutdown of the redundant LANE Services to force all LECs to return
to the primary LANE Services after a failure has occurred.
Achieving a new LES configuration when updated (invoked by the
switch software automatically), for example, frame size change.
Troubleshooting, when there are problems with the connections of
LECs to the LES.
Resets general LAN Emulation statistics for a specified ELAN to zero.
Command Actions
Command Result
Example
Enter:
2 2 5 2
The following prompt appears:
Are you sure (y/n): y
Enter
Y
to confirm,
N
to cancel the reset request.
ELAN with ELAN ID 2 is reset.
Enter menu sequence:
(2) LEM: LAN Emulation
(2) LES: LE Services
(5) RST: LES Restart ELAN
Enter a parameter at the prompt
Parameter Format or Range
ELAN ID
1
16
For more information, see “Display ELAN Parameters in
LES Database” on page 283.
Direct access sequence:
2 2 5
[parameters]
System action taken:
Specified ELAN is reset.
System message display:
ELAN is reset.