3Com 9000 Switch User Manual


 
Setting Up for Management
69
Update Ethernet
Encapsulation Type
Update the Ethernet encapsulation type of the CoreBuilder 9000 ATM
Enterprise Switch. The options are:
1-ETH: Standard encapsulation — according to 802.3
0-LLC: Enhanced encapsulation
The default Ethernet encapsulation type is 1-ETH.
For more information, see “Ethernet Encapsulation Type” on page 172 in
the Operations Guide.
The Ethernet encapsulation type is updated after the next reboot.
Command Actions
Command Result
Example
Enter:
1 1 2 7 2 1
The following message is displayed:
Eth Type was successfully set for the next reboot.
The Ethernet encapsulation type is updated to ETH and takes effect after
the next reboot.
Enter the menu sequence:
(1) SYS: Platform Configuration
(1) SET: Switch Setup
(2) MNG: Management Setup
(7) ETH: Ethernet Type Setup
(2) SET: Set Ethernet Type
Enter a parameter at the prompt
Parameter Format or Range
Ethernet encapsulation
type
1
for type ETH
0
for type LLC
Direct access sequence:
1 1 2 7 2
[parameters]
System action taken:
The Ethernet encapsulation type is updated.
System message display:
Eth Type was successfully set for the
next reboot.