LAN Emulation Redundancy
269
Assign Redundant
LES to ELAN
Assign a LES to be the redundant (secondary) LES of a specified ELAN in
the LECS database. Specify the ELAN name and the ATM address of the
LES. The secondary LES should reside on a different switch than the
primary LES. For more information, see “LES Redundancy Facility —
Configuring the ELAN Topology Database” on page 139 in the
Operations Guide.
Command Actions
Command Result
Example
Enter:
2 1 5 9 1 elan73_9
47.0.0.0.0.0.3c.0.0.d0.0.0.0.0.1.2.3.4.5.6
The following message is displayed:
Redundant LES successfully added.
The specified LES is assigned to be the secondary LES for the specified
ELAN in the LECS database.
Enter menu sequence:
(2) LEM: LAN Emulation
(1) LCS: LE Configuration Service
(5) LNT: LECS Network topology
(9) RDN: LE Service redundancy
(1) ALS: Add redundant LES to
elan
Enter a parameter at the prompt
Parameter Format or Range
ELAN name Up to 32 characters. For more information, see “Add
ELAN” on page 259.
LES ATM address 20 Hex bytes separated by periods
Direct access sequence:
2 1 5 9 1
[parameters]
System action taken:
The specified LES is assigned to be the secondary LES
for the specified ELAN in the LECS database.
System message display: