3Com 9000 Switch User Manual


 
370
C
HAPTER
11: C
ONFIGURING
AND
M
ANAGING
PNNI
Set SVCC Retry Time
Sets the SVCC (Switch Virtual Channel Connection) retry time. The SVCC
retry time is the time that the specified node will delay after a viable
SVCC-based RCC is unexpectedly taken down, before attempting to
reestablish it. A change to the SVCC retry time takes place after the next
reboot.
Command Actions
Command Result
Example
Enter:
1 1 9 4 3 4 14 20
The following message is displayed:
Default Value is 30, new value is 20
Press ENTER to continue...
Enter menu sequence:
(1) SYS: Platform Configuration
(1) SET: Switch setup
(9) PNI: PNNI Setup
(4) CFP: Configure PNNI
(3) NCF: Node Configuration
(4) TIM: Timers
(14) SRT: SVCC Retry Time
Enter a parameter at the prompt
Parameter
Format or Range
initiation time 1 - 60000 seconds
Direct access sequence:
1 1 9 4 3 4 14
[parameters]
System action taken:
The SVCC retry time is displayed and is updated to its
new value.
System message display:
Default value is <x>. New value is <y>