3Com 9000 Switch User Manual


 
Setting the Timers
371
Set SVCC Calling
Integrity Time
Sets the SVCC calling integrity time. The SVCC calling integrity time is the
default value used to initiate the SVCC integrity timer at the node that
initiates a switched virtual circuit at a logical group node. A change to the
SVCC calling integrity time takes place after the next reboot.
Command Actions
Command Result
Example
Enter:
1 1 9 4 3 4 15 20
The following message is displayed:
Default Value is 35, new value is 20
Press ENTER to continue...
Enter menu sequence:
(1) SYS: Platform Configuration
(1) SET: Switch setup
(9) PNI: PNNI Setup
(4) CFP: Configure PNNI
(3) NCF: Node Configuration
(4) TIM: Timers
(15) SCI: SVCC Calling Integrity
Time
Enter a parameter at the prompt
Parameter
Format or Range
integrity time 1 - 60000 seconds
Direct access sequence:
1 1 9 4 3 4 15
[parameters]
System action taken:
The SVCC calling integrity time is displayed and is
updated to its new value.
System message display:
Default value is <x>, new value is <y>