Lucent Technologies R8r Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Upgrading R5si/R6si to R8r EPN and Adding Memory
3-47Release 5/6si to Release 8r
3
Verify Usable Circuit Pack Vintages
1. Verify every circuit pack reused in the upgrade conforms to the usable
vintage requirements for a Release 8r system (see
Reference Guide for
Circuit Pack Vintages and Change Notices
).
Install System Access Ports
1. Before connecting various endpoints that use EIA interfaces to the system,
install up to 8 loop-around connections for Mode 2-to-Mode 3 (and vice
versa) data conversion.
From the
outgoing
perspective of the system communicating with an EIA
endpoint, these loop-around connections convert Mode 3 data (circuit-switched
packet data, with undefined bit rates and packet specifications) to Mode 2 data
(low-speed, usually asynchronous, data at rates of 300 to 19,200 bps) by:
Accepting Mode 3 data off the LAN bus (from the SPE) at a TN553 Packet
Data Line circuit pack, where Mode 3-to-Mode 2 conversion is done
Routing the converted data through the cross-connect field and back to a
TN726B Data Line where the equivalent Mode 2 data can access the TDM
bus, for subsequent routing to an EIA endpoint
The endpoints that use these EIA interfaces and, therefore, require the Mode
2-to-Mode 3 conversion include:
Generic 3 Management Applications (G3-MA)
Remote Management Terminal
Basic Call Management System (BCMS) terminal
Call Detail Recording Unit (CDRU)/Centralized Attendant Service Plus
(CAS+)
Property Management System (PMS)
Printers
Reseat DEFINITY LAN Gateway System
1. Reseat the DEFINITY LAN Gateway assembly into the backplane.
Reseat DEFINITY AUDIX System
1. Reseat the AUDIX assembly to its backplane connectors.
Remove Emergency Transfer Ground Wire
1. Remove the ground wire from the emergency transfer unit.