Lucent Technologies R8r Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
What’s New in Release 8.2r
xiii
Upgrade tips
The following upgrade tips were generated from problems identified in the
laboratory or during early introduction.
Adding a third memory circuit pack and an optical drive requires a second
non-call-preserving service interruption. See Chapter 1, ‘‘Upgrading
G3rV2, V3, V4 to R8r and Adding Memory’’.
When upgrading a DEFINITY ECS R8r to a duplicated system (B carrier)
or adding a switch node carrier (D carrier), you may receive a carrier that
looks different than the ones currently installed. The enhanced carriers
come with 16 grounding straps that connect to the carrier connector
panel. See ‘‘Add a Control Carrier (Add Duplication)’’ on page 6-80
, ‘‘Add
a Switch Node Carrier (Standard Reliability)’’ on page 6-94, and ‘‘Add a
Switch Node Carrier (High or Critical Reliability)’’ on page 6-108.
NOTE:
An enhanced carrier is used only in an R8r PPN cabinet that uses
either AC power (U.S.) or Global power.
Cautions and warnings
The following new cautions and warnings were generated from problems
affecting possible data loss that were identified in the laboratory or during early
introduction.
Procedure Caution or Warning
Unlock the Active SPE
(H/C only)
!
CAUTION:
Allow 10 minutes after unlocking to make sure the standby
SPE has fully returned to service.
Upgrade Software
!
CAUTION:
All calls are dropped—this is a service interruption