G3vs with Intel 386 or Risc Processor to R8r
4-3Read This First
4
Usable Circuit Packs
Every circuit pack used in the Release 8 system must conform to the minimum
usable vintage requirements for that system. At a presale site inspection, the
remediation process checks the vintages of existing circuit packs to be reused in
the Release 8 system. Circuit packs with unusable vintages must be replaced.
Refer to
Technical Quarterly
,
Reference Guide for Circuit Pack Vintages, Change
Notices,
and to the
Software Release Letter
, for information about usable circuit
pack vintages. For information about usable vintages of non-United States circuit
packs, refer to the ITAC’s Tech Alert from your regional distributor.
Contact Network Technicians
Contact the technician for each public and private network accessed by the
system before the upgrade begins. Otherwise, it is possible that network-access
trunk facilities will be busied out at the far end.
Required Tools
The following tools and items may be required during the upgrade:
1/4-inch flat blade screwdriver
1/4-inch socket with ratchet (optional)
Long-nose pliers to straighten backplane pins
Static-proof or original circuit pack packaging for transporting circuit
packs
Labels for identifying the port circuit packs and cables attached to the
rear of cabinets
One dozen #8 self-tapping screws
Repair kit for backplane pins (KS-22876 L2 or equivalent)
One copy of each of the following manuals:
DEFINITY Enterprise Communications Server Release 8
Maintenance for R8r
DEFINITY Enterprise Communications Server Release 8
Administrator’s Guide