Lucent Technologies R8r Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-54Add IP Interface Assembly
6
.
6. If not, type MEDPRO in the slot just above TN802B slot and press Enter.
Changing the one entry automatically changes the entry above it. If it is in
IP Trunk mode, you get the following error message:
MedPro type requires TN802 with application. Type
MEDPRO on circuit-packs form.
7. Type
change ip-interfaces
and press
Enter.
8. Type in the information for the TN802B IP Interface,
9. Set the
Enabled
field to
y
, and press
Enter.
NOTE:
The customer provides the IP address, subnet mask, and gateway
address.
At this time the TN802B LCD reads
PC BOOT *
, and about 3 to 4 minutes
later reads
MEDPRO *
with the asterisk flashing
change circuit-packs Page 1 of 5
CIRCUIT PACKS
Cabinet: 1 Carrier: A
Carrier Type: processor
Slot Code Sf Mode Name Slot Code Sf Mode Name
11: MEDPRO RESERVED-IP
01: TN754 DIGITAL LINE 12: MEDPRO RESERVED-IP
02: TN758 POOLED MODEM 13: TN802 B MAPD BOARD
03: TN2144 ANALOG LINE 14:
04: TN746 B ANALOG LINE 15:
05 16:
06: TN771 C MAINTENANCE/TEST
07: TN464 F DS1 INTERFACE
08: TN2140 E&M TIE TRUNK
09: TN767 E DS1 INTERFACE
10: TN799 B CONTROL-LAN
’#’ indicates circuit pack conflict.