Upgrading R5r/R6r/R7r to R8r without Adding Memory
2-20Upgrade the software and hardware
2
Enable Customer Options and Alarm Origination
to INADS
1. Get the DOSS order number of the upgrade from the project manager and
ask the regional Customer Software Administration to complete the steps
in the shaded box. See ‘‘Where to Call for Technical Support’’ on page -xx
for telephone numbers.
NOTE:
As part of the system registration process, the INADS Database
Administrator enables Alarm Origination.
2. When administration is completed, log in as
craft
.
Check SPE status (H/C only)
1. Type
status SPE
and press Enter. Wait until
The
Standby Refreshed
field shows
yes
The
Standby Shadowing
field shows
on
The
Standby Handshake
field shows
up
Save Translations
1. Type
save translation
and press Enter to copy upgraded translations to
the system disk, which takes about 2 minutes.
"init" login administration:
1. Log in as
init
.
2. Type
change system-parameters customer-options
and press
Enter
to verify that the customer options are properly set.
3. Go to screen 6, QSIG Optional Features, and set the
Basic Call
Setup
field to
y
if the customer was using Supplementary Services
Protocol b or d on an ISDN-PRI trunk group before the upgrade.
4. Type
change system-parameters offer-options
and press
Enter.
5. If the
Activate Offer
field is
n
, set it to
y
and press
Tab . A warning
message lets you know whether you need to save translations and
reboot to make the change permanent.
6. Press
Enter to effect the changes or Cancel if there were no changes.
7. Contact the requester when done.